Freeze-thaw resistance of concrete products

New research findings

The freeze-thaw resistance of concrete paving blocks must be verified by the slab test (DIN EN 1338). Sometimes clients in Germany demand the CDF method (DIN CEN/TS 12390-9). Independent of the test method used there are some discrepancies between the laboratory test results and the real-life behavior of paving blocks installed. It is, for example, reported that there were some cases in which the facing layer of installed concrete paving blocks detached from the core concrete after only a few winter seasons despite the fact that these products had previously passed the CDF tests. Within the IGF research project No. 17996 N, VDZ and University of Kassel investigated how a purposeful forecast of the scaling behavior of areas paved with concrete blocks is possible by the above-mentioned test methods.

It is common practice to test only the face concrete of double-layer concrete paving blocks. This can lead to an incorrect evaluation of the freeze-thaw resistance of concrete paving blocks. A highly water-saturated core concrete with a low freeze-thaw-resistance can contribute to spalling of the face concrete after installation. Concrete paving blocks installed on a base layer of gravel were investigated in the research project under practice-oriented installation and environmental conditions in a freeze chamber. The consistence of the results obtained by the slab test of the face and core concrete with the damage behavior observed in the freeze chamber was higher than that achieved by the CDF method.

In addition to testing the face concrete, it is highly recommended to test the freeze-thaw resistance of the core concrete by means of the slab test. Robust concrete compositions with an appropriate cement content should be used for the core concrete, too. The risk of failure of installed concrete paving blocks is diminished in this way. Possibly DIN EN 1338 will stipulate the core concrete test by means of the slab test. Until then, contracting authorities could require such verification.

x

Related articles:

Issue 09/2019

Reliable assessment of resistance of concrete paving blocks to freeze-thaw with de-icing salt

Verification of the resistance of concrete paving blocks to freeze-thaw with de-icing salt in accordance with DIN EN 1338 [DIN38 has been required from manufacturers since 2005. The test method for...

more
Issue 01/2020

Assessment of frost and freeze-thaw damage to concrete pavers (Part 2)

The first part of this article dealt with the different patterns associated with freeze-thaw damage, the impact of cracks occurring in products, and the influence of installation and use on the onset...

more
Issue 02/2013 Current findings with respect to the XF2 freeze/thaw test method

Freeze/thaw resistance at moderate water saturation levels

Generally accepted, internationally recognized methods (CIF and CDF) exist for testing the freeze/thaw resistance of concrete at high water saturation rates irrespective of the simultaneous action of...

more
Issue 02/2016 Transferability of laboratory test results

Determining freeze-thaw resistance of precast products for road pavements under real-life conditions

Since February 2005, the freeze-thaw resistance of concrete pavers had to be determined in the modified slab test in accordance with DIN EN 1338. Some clients favor the CDF method even though there...

more
Issue 12/2019

Assessment of frost and freeze-thaw damage to concrete pavers (Part 1)

High weather resistance of concrete pavers is crucial wherever paved surfaces are exposed to frequent freeze-thaw cycles. In this respect, it should be noted that the climatic conditions prevailing in...

more