Subsequent reinforcement connection system with approval

The subject of “omitted or mistaken reinforcement bars” is well known. The professional solution with the injection mortar Epcon C8 of Betomax is aiming at any typical kind of connecting new components to existing building structures, in case of refurbishments, omitted columns up to subsequently attached stair landings and staircase.
The application of a subsequently constructed reinforcement connection by means of the injection mortar Epcon C8 is clearly regulated by the German building authority approval Z-21.8-1866 and the European technical approval ETA-07/0189. The scope of application extends to reinforcement bars type BSt 500 S of diameters from 8 mm to 32 mm in accordance with the German standard DIN 488-1:1984-09.
It is allowed to use a reinforcement connection in normal-density concrete of at least strength class C12/15 up to C50/60 at most. But provided that the drilled holes are made by heavy-duty hammer drill or diamond drill. The following anchorage may be made in dry or wet concrete, however not in drilled holes filled with water. Beside the determining safety benefits, the reactive mortar is adjusted for a long processing time. Thus, it is ensured that the mortar can be filled uniformly into the drilled hole without any pressure of time with the aid of the accessory cartridge applicator gun.
The subsequent reinforcement connection is calculated in accordance with the German standard for reinforced concrete DIN 1045-1. Connections obtained by overlapping joints with the reinforcement of the construction element and the anchoring of the reinforcement at the bearings of slabs or beams, of construction elements having to bear above all pressure, as well as in order to cover the tensile forces, are approved by building authorities.   

Address/Anschrift
Betomax® Kunststoff- und Metallwarenfabrik GmbH & Co. KG
Dyckhofstraße 1
41460 Neuss/Germany
Tel.: +49 2131 2797-0
Fax: +49 2131 2797-70
info@betomax.de
www.betomax

Related articles:

Issue 12/2022 FISCHER

New RebarConnect FIS RC II injection mortar

Whether connections of new walls, columns or stairs are concerned or closing of existing floor openings, constructing of ground slabs, concrete floors or extending of foundations – subsequently...

more
Issue 01/2010 Subsequent connection

Reinforcement systems for subsequently connected reinforced-concrete brackets

What solutions are available? As a solution, Halfen company provides two different versions for a subsequent connection. One option is the Halfen HBT Rebend Connection type 7. The closed casing is...

more

A new kind of cable loop connection system with DIBt approval

Precast construction is related to efficient manufacturing of precast concrete components and short construction periods. Therefore, also the connection of the elements among each other has to be...

more
Issue 08/2016 Betomax

Punching shear and bonded reinforcement system

Flat slabs and/or element floors (precast slabs with in-situ structural concrete topping) as used in industrial and commercial buildings are state-of-the-art and allow great freedom in plan design....

more
Issue 06/2018 SOLIDIAN/KEMMLER

A precast garage with glass fiber reinforcement and with national technical approval

The use of textile concrete enables  easier and more environmentally friendly manufacture of precast garages. In a cooperation of Solidian, Beton Kemmler and RWTH Aachen University of Technology, a...

more